TN-5500AϵÁÐ

EN 50155 8/8+2G/16+2G¿ÚǧÕ×ÒÔÌ«Íø½»Á÷»ú

  • ¶à´ï 2 ¸öǧÕ×ÒÔÌ«Íø¶Ë¿Ú £¬´øÅÔ·Öм̹¦Ð§¿ÉÑ¡
  • Ö§³Ö 8 ¸öÇÐºÏ IEEE 802.3at/af ±ê×¼µÄ PoE ¶Ë¿Ú
  • 24 ÖÁ 110 VDC ¸ôÀëµçÔ´ÊäÈë
  • ÇкÏEN 50155 Ç¿ÖÆÐÔ²âÊÔÏîÄ¿ ±¾²úÆ·ÊÊÓÃÓÚ EN 50155 ±ê×¼½ç˵µÄ¹ìµÀ³µÁ¾¹ì½»Ó¦Óá£ÓйØÏêϸ˵Ã÷ £¬Çë²ÎÔÄ£ºwww.moxa.com/doc/specs/EN_50155_Compliance.pdf
  • Ö§³Ö -40 ÖÁ 75¡ãC ÊÂÇéζÈ
  • Ö§³Ö Turbo Ring ºÍ Turbo Chain£¨×ÔÓúʱ¼ä < 20 ms @ 250 ̨½»Á÷»ú£© £¬ÒÔ¼° RSTP/STP/MSTP ÍøÂçÈßÓà
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ToughNet TN-5500A ϵÁÐ M12 Íø¹ÜÐ͹¤ÒµÒÔÌ«Íø½»Á÷»úרΪÑÏ¿ÁÇéÐÎÖеĹ¤ÒµÓ¦ÓöøÉè¼Æ¡£ TN-5500A ϵÁн»Á÷»úͨ¹ýÀο¿µÄ M12 ÌÖÂÛϸÃܵء¢Àο¿µÄÅþÁ¬ £¬¿ÉÈ·±£ÍøÂç×°±¸Îȹ̵ØÔËÐÐ £¬¶ø²»Ðèµ£ÐÄÍâÔÚÇéÐεÄÕñ¶¯ºÍ¹¥»÷µÈ×ÌÈÅËùÔì³ÉµÄÎÊÌâ¡£TN-5500A ϵÁÐÅ䱸 8 ¸ö»ò 16 ¸ö°ÙÕ×ÒÔÌ«Íø M12 ¶Ë¿Ú £¬Ö§³Ö°üÀ¨ 8 ¸öÇÐºÏ IEEE 802.3at/af ±ê×¼µÄ PoE£¨ÒÔÌ«Íø¹©µç£©¶Ë¿Ú¡¢2 ¸öÔڵײ¿µÄ¶Ë¿Ú¿ÉÌṩǧÕ×ÒÔÌ«Íø½Ó¿Ú £¬ÒÔ¼°Ò»¸ö´øÅÔ·Öм̹¦Ð§¿ÉÑ¡¡£PoE ½»Á÷»ú¿É×÷Ϊ¹©µç×°±¸ (PSE) £¬Ã¿¸ö¶Ë¿Ú¹©µç¿É´ï 30 W ¹¦ÂÊ £¬ÊʺÏΪÇÐºÏ IEEE 802.3at/af ±ê×¼µÄÊܵç×°±¸¹©µç £¬Èç IP ¼à¿Ø¡¢ÎÞÏß½ÓÈëºÍ IP µç»°¡£
TN-5500A ϵÁÐÖ§³Ö 24/36/48/72/96/110 VDC µÄ¿í¹æÄ£µçÔ´ÊäÈë £¬¿ÉÔÚÈ«Çò²î±ðËùÔÚʹÓÃͬÑùµÄÊäÈëµçÔ´¡£±ðµÄ £¬24 ÖÁ 110 VDC ¿í¹æÄ£µçÔ´ÊäÈëºÍ¸ôÀëµçÔ´ÔöÇ¿ÁËϵͳµÄÎȹÌÐÔ¡£-40 ÖÁ 75¡ãC ÊÂÇéÎÂ¶ÈºÍ IP54 ·ÀË®Íâ¿Ç £¬ÔÊÐíÆäÔÚ±°ÁÓÇéÐÎϾÙÐа²ÅÅ¡£TN-5500A ϵÁÐÒÔÌ«Íø½»Á÷»úÇÐºÏ EN 50155 µÄÇ¿Öƹæ¸ñ £¬°üÀ¨²Ù×÷ζȡ¢µçÔ´ÊäÈëµçѹ¡¢ÀËÓ¿¡¢ESD ºÍÕñ¶¯ £¬ÒÔ¼°± £»¤Í¿²ãºÍµçÔ´¾øÔµ £¬Ê¹ÆäÊÊÓÃÓÚÖÖÖÖ¹¤ÒµÓ¦Óá£

ÆäËûÌصãºÍÓÅÊÆ
? ÔÚÿ̨½»Á÷»ú×ܹ¦ÂÊÔ¤ËãΪ 120W µÄÇéÐÎÏ £¬Ã¿¸ö PoE ¶Ë¿Ú¹©µç¿É´ï 30W µÄ¹¦ÂÊ
? IPv6 Ready ±ê¼ÇÈÏÖ¤£¨IPv6 ±ê¼ÇίԱ»áÈÏÖ¤£©
? ÏȽøµÄ EN 50155 PoE ½»Á÷»ú £¬ÊÊÓÃÓÚ¹ìµÀ³µÁ¾Ó¦ÓÃ
? DHCP Option 82 £¬ÓÃÓÚ²î±ðÕ½ÂÔ·ÖÅÉ IP µØµã
? Ö§³Ö Turbo Ring ºÍ Turbo Chain£¨×ÔÓúʱ¼ä < 20 ms @ 250 ̨½»Á÷»ú£© £¬ÒÔ¼° RSTP/STP/MSTP ÍøÂçÈßÓà
? IGMP snooping ºÍ GMRP £¬ÓÃÓÚ¹ýÂË×é²¥Á÷Á¿
? Ö§³Ö EtherNet/IP ºÍ Modbus TCP ¹¤ÒµÒÔÌ«ÍøЭÒé
? »ùÓÚ¶Ë¿ÚµÄ VLAN¡¢IEEE 802.1Q VLAN ºÍ GVRP £¬¿É¼ò»¯ÍøÂçÍýÏë
? QoS£¨IEEE 802.1p/1Q ºÍ ToS/DiffServ£©Ö§³Ö¶ÔʵʱÁ÷Á¿µÄ·Ö¼¶ºÍÅÅÐò
? IEEE 802.3ad¡¢LACP £¬¿ÉÓÅ»¯ÍøÂç´ø¿í
? SNMPv1/v2c/v3 Ö§³Ö²î±ð¼¶±ðµÄÍøÂçÖÎÀí
? TACACS+¡¢SNMPv3¡¢IEEE 802.1X¡¢HTTPS ºÍ SSH £¬ÓÃÓÚÔöÇ¿ÍøÂçSAFETY
? RMON Ö§³Ö×Ô¶¯µÄÍøÂç¼à¿Ø
? ´ø¿íÖÎÀí £¬¿ÉÔ¤·À·ºÆð²»Îȹ̵ÄÍøÂç״̬
? »ùÓÚ MAC µØµãµÄ¶Ë¿ÚËø¶¨¹¦Ð§ £¬±ÜÃâδ¾­ÊÚȨµÄ»á¼û
? Ö§³Ö¶Ë¿Ú¾µÏñ¹¦Ð§ £¬±ãÓÚÔÚÏßµ÷ÊÔ
? ͨ¹ýµç×ÓÓʼþºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯·¢³öÒì³£ÖÒÑÔ
? ¿ìËÙ»»Ï߻ָ´
? LLDP Ö§³Öͨ¹ýÍøÂçÖÎÀíÈí¼þ×Ô¶¯·¢Ã÷ÍøÂçÍØÆË
? ͨ¹ý web ä¯ÀÀÆ÷¡¢Telnet/´®¿Ú console¡¢CLI ºÍ Windows ÖÎÀí¹¤¾ß¾ÙÐÐÉèÖÃ
? »·Â·± £»¤±ÜÃâÍøÂ绷·
? Ö§³ÖÃæ°åʽװÖûòµ¼¹ìʽװÖÃ

ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
 ±¨¾¯¹¦Ð§Í¨µÀ :2 x ¼ÌµçÆ÷Êä³ö £¬½ÓÄÉ 1 ¸ö M12 A-coded 5-pin ¹«Í·ÌÖÂÛ £¬´¿µç×èÐÔ¸ºÔØ£º1 A @ 30 VDC

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100/1000BaseT(X) ¶Ë¿Ú £¬Q-ODC ¹âÏËÌÖÂÛ: 
TN-5510A-2GLSX ϵÁУº 2
TN-5510A-8PoE-2GLSX ϵÁУº2
10/100/1000BaseT(X) ¶Ë¿Ú£¨M12 X-coded 8-pin ĸͷÌÖÂÛ£©: 
TN-5510A-2GTX ϵÁУº2
TN-5510A-8PoE-2GTX ϵÁУº2
TN-5518A-2GTX ϵÁУº2
TN-5518A-8PoE-2GTX ϵÁУº2
10/100/1000BaseT(X) ¶Ë¿Ú£¨M12 X-coded 8-pin ĸͷÌÖÂÛ £¬´øÅÔ·¹¦Ð§£© :
TN-5510A-2GTXBP ϵÁУº2
TN-5510A-8PoE-2GTXBP ϵÁУº2
10/100BaseT(X) ¶Ë¿Ú£¨M12 D-coded 4-pin ¿×ʽÌÖÂÛ£© 
TN-5508A/5510A ϵÁÐ·Ç PoE Ðͺţº8
TN-5516A/5518A ϵÁÐ·Ç PoE Ðͺţº16
TN-5516A/5518A ϵÁÐ PoE Ðͺţº8
PoE ¶Ë¿Ú£¨10/100BaseT(X) £¬M12 D-coded 4-pin ĸͷÌÖÂÛ£© :
TN-5500A ϵÁÐ PoE Ðͺţº8
±ê×¼ :
IEEE 802.1D-2004 £¬ÓÃÓÚÌìÉúÊ÷ЭÒé (STP)
IEEE 802.1p £¬ÓÃÓÚЧÀÍÆ·¼¶
IEEE 802.1Q £¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.1s £¬ÓÃÓÚ¶àÌìÉúÊ÷ЭÒé (MSTP)
IEEE 802.1w £¬ÓÃÓÚ¿ìËÙÌìÉúÊ÷ЭÒé (RSTP)
IEEE 802.1X £¬ÓÃÓÚÊÚȨÈÏÖ¤
IEEE 802.3 £¬ÓÃÓÚ 10BaseT
IEEE 802.3ab £¬ÓÃÓÚ 1000BaseT(X)
IEEE 802.3ad £¬ÓÃÓÚ LACP ¶Ë¿Ú¾ÛºÏ
IEEE 802.3u £¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX
IEEE 802.3x £¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
TN-5500A ϵÁÐ PoE ÐͺţºIEEE 802.3af/at £¬ÓÃÓÚ PoE/PoE+ Êä³ö
TN-5510A ϵÁÐ 2GLSX ÐͺţºIEEE 802.3z £¬ÓÃÓÚ 1000BaseSX/LX/LHX/ZX

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¹ã²¥×ª·¢ :IP ¶¨Ïò¹ã²¥ £¬¹ã²¥×ª·¢
ÉèÖÃÑ¡Ïî :
ÏÂÁîÐнçÃæ (CLI) £¬Í¨¹ý´®¿Ú/Telnet/SSH µÄÏÂÁîÐнçÃæ (CLI) £¬Web Console (HTTP/HTTPS) £¬Windows ÖÎÀí¹¤¾ß
¹ýÂË :802.1Q¡¢GMRP¡¢GVRP¡¢IGMP v1/v2/v3¡¢»ùÓÚ¶Ë¿ÚµÄ VLAN¡¢¾²Ì¬×é²¥
¹¤ÒµÐ­Òé:EtherNet/IP Adapter (Slave), Modbus TCP Server (Slave)
ÖÎÀí :
Back Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢DHCP Option 66/67/82¡¢DHCP Server/Client¡¢Flow control£¨Á÷Á¿¿ØÖÆ£©¡¢HTTP¡¢IPv4/IPv6¡¢IOxpress¡¢LLDP¡¢Port Mirror£¨¶Ë¿Ú¾µÏñ£©¡¢QoS/CoS/ToS¡¢RARP¡¢RMON¡¢SMTP¡¢SNMP Inform¡¢SNMP Trap¡¢Syslog¡¢Telnet ºÍ Account Management£¨ÕË»§ÖÎÀí£©
MIB :
Bridge MIB¡¢Ethernet-like MIB¡¢MIB-II¡¢P-BRIDGE MIB¡¢Q-BRIDGE MIB¡¢RMON MIB Groups 1¡¢2¡¢3¡¢9¡¢RSTP MIB
ÈßÓàЭÒé:Á´Â·¾ÛºÏ¡¢MSTP¡¢RSTP¡¢STP¡¢Turbo Chain¡¢Turbo Ring v1/v2¡¢´ø DRC µÄ Turbo Ring
SAFETY:¹ã²¥·ç±©± £»¤¡¢HTTPS/SSL¡¢ÍâµØÕÊ»§»á¼ûÖÎÀí¡¢TACACS+¡¢¶Ë¿ÚËø¶¨¡¢RADIUS¡¢ËÙÂÊÏÞÖÆºÍ SSH
¶ÔʱЧÀÍ:IEEE 1588 PTP v1/v2¡¢NTP Server/Client¡¢SNTP

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IGMP ·Ö×é :256
max. VLAN ÊýÄ¿:64
VLAN ID ¹æÄ£ :VID 1 ÖÁ 4094

LED ½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
 LED ָʾµÆ :STATE¡¢PWR1¡¢PWR2¡¢FAULT¡¢10/100/1000M

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú:M12 A-coded ¹«Í·ÌÖÂÛ

µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊäÈëµçÁ÷ :
TN-5508A-WV ϵÁУº0.28 A @ 24 VDC, 0.07 A @ 110 VDC
TN-5508A-8PoE ϵÁУº7.6 A @ 24 VDC, 1.55 A @ 110 VDC
TN-5510A-2GTXBP ϵÁУº0.56 A @ 24 VDC, 0.13 A @ 110 VDC
TN-5510A-2GLSX ϵÁУº0.45 A @ 24 VDC, 0.1 A @ 110 VDC
TN-5510A-8PoE-2GTX ϵÁУº7.90 A @ 24 VDC, 1.61 A @ 110 VDC
TN-5510A-8PoE-2GLSX ϵÁУº7.80 A @ 24 VDC, 1.58 A @ 110 VDC
TN-5516A-WV ϵÁУº0.39 A @ 24 VDC, 0.09 A @ 110 VDC
TN-5516A-8PoE ϵÁУº8.37 A @ 24 VDC, 1.65 A @ 110 VDC
TN-5518A-2GTX ϵÁУº0.68 A @ 24 VDC, 0.16 A @ 110 VDC
TN-5518A-8PoE-2GTX ϵÁУº8.66 A @ 24 VDC, 1.69 A @ 110 VDC
ÊäÈëµçѹ :24/36/48/72/96/110 VDC £¬ÈßÓàË«µçÔ´ÊäÈë
µçÔ´ÊäÈëÊýÄ¿:
TN-5500A ϵÁÐ·Ç PoE Ðͺţº2
TN-5500A ϵÁÐ PoE Ðͺţº1
ÊÂÇéµçѹ:16.8 ÖÁ 137.5 VDC
¹ýÔصçÁ÷± £»¤:Ö§³Ö
µçÔ´ÌÖÂÛ :M23 ÌÖÂÛ
·´½Ó± £»¤ :Ö§³Ö
PoE ¹¦ÂÊÔ¤Ëã×ÜÁ¿ :TN-5500A ϵÁÐ PoE Ðͺţº120 W

»úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Íâ¿Ç :½ðÊô
IP Æ·¼¶:IP54
³ß´ç :
TN-5508A ϵÁÐ·Ç PoE Ðͺţº185 x 175.8 x 76 mm£¨7.28 x 6.92 x 2.99 Ó¢´ç£©
TN-5508A ϵÁÐ PoE Ðͺţº185 x 175.8 x 115 mm£¨7.28 x 6.92 x 4.53 Ó¢´ç£©
TN-5510A ϵÁÐ·Ç PoE Ðͺţº185 x 180.9 x 76 mm£¨7.28 x 7.12 x 2.99 Ó¢´ç£©
TN-5510A ϵÁÐ PoE Ðͺţº185 x 180.9 x 115 mm£¨7.28 x 7.12 x 4.53 Ó¢´ç£©
TN-5510A-2GLSX-ODC ϵÁУº185 x 204.3 x 76.0 mm£¨7.28 x 8.04 x 2.99 Ó¢´ç£©
TN-5510A-8PoE-2GLSX-ODC ϵÁУº185 x 219.3 x 115 mm£¨7.28 x 8.63 x 4.53 Ó¢´ç£©
TN-5516A ϵÁÐ·Ç PoE Ðͺţº250 x 175.8 x 76 mm£¨9.84 x 6.92 x 2.99 Ó¢´ç£©
TN-5516A ϵÁÐ PoE Ðͺţº250 x 175.8 x 115 mm£¨9.84 x 6.92 x 4.53 Ó¢´ç£©
TN-5518A ϵÁÐ·Ç PoE Ðͺţº250 x 180.9 x 76 mm£¨9.84 x 7.12 x 2.99 Ó¢´ç£©
TN-5518A ϵÁÐ PoE Ðͺţº250 x 180.9 x 115 mm£¨9.84 x 7.12 x 4.53 Ó¢´ç£©
ÖØÁ¿ :
TN-5508A ϵÁÐ·Ç PoE Ðͺţº1,610 g (3.54 lb)
TN-5508A ϵÁÐ PoE Ðͺţº2,383 g (5.25 lb)
TN-5510A ϵÁÐ·Ç PoE Ðͺţº1,805 g (3.97 lb)
TN-5510A ϵÁÐ PoE Ðͺţº2,690 g (5.93 lb)
TN-5516A ϵÁÐ·Ç PoE Ðͺţº2,138 g (4.71 lb)
TN-5516A ϵÁÐ PoE Ðͺţº3,286 g (7.24 lb)
TN-5518A ϵÁÐ·Ç PoE Ðͺţº2,250 g (4.96 lb)
TN-5518A ϵÁÐ PoE Ðͺţº3,439 g (7.58 lb)
×°Öà :µ¼¹ìʽװÖ㨿ÉÑ¡£©¡¢±Ú¹ÒʽװÖÃ
± £»¤ :TN-5500A ϵÁÐ-CT ÐͺţºPCB ± £»¤Í¿²ã

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéζÈ:-40 ÖÁ 75¡ãC£¨-40 ÖÁ 167¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£©:-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È :5 ÖÁ 95%£¨·ÇÀäÄý£©
º£°Î :2000 m

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EMC :EN 55032/24
EMS :
IEC 61000-4-2 ESD£º½Ó´¥£º6 kV £»¿ÕÆø£º8 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º20 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º2 kV £»Ðźţº2 kV
IEC 61000-4-5 Surge£ºµçÔ´£º2 kV £»Ðźţº2 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8 PFMF
×ÔÓÉÂäÌå :IEC 60068-2-31
ÉäƵ :FCC
¹ìµÀ½»Í¨:EN 50121-4¡¢EN 50155¡¢IEC 60571
¹ìµÀ»ðÔÖ·À»¤:EN 45545-2
SAFETY :IEC 60950-1¡¢UL 61010-2-201
¹¥»÷ :IEC 60068-2-27 £¬IEC 61373 £¬EN 50155
Õñ¶¯ :IEC 60068-2-64 £¬IEC 61373 £¬EN 50155

ÉùÃ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÂÌÉ«²úÆ·:RoHS¡¢CRoHS¡¢WEEE

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä :
TN-5508A-WV ϵÁУº814,964 Сʱ
TN-5508A-8PoE ϵÁУº526,372 Сʱ
TN-5510A-2GTX ϵÁУº758,855 Сʱ
TN-5510A-2GTXBP ϵÁУº742,880 Сʱ
TN-5510A-2GLSX ϵÁУº722,049 Сʱ
TN-5510A-8PoE-2GTX ϵÁУº502,756 Сʱ
TN-5510A-8PoE-2GTXBP ϵÁУº495,703 Сʱ
TN-5510A-8PoE-2GLSX ϵÁУº486,560 Сʱ
TN-5516A-WV ϵÁУº722,721 Сʱ
TN-5516A-8PoE ϵÁУº722,721 Сʱ
TN-5516A-2GTX ϵÁУº647,128 Сʱ
TN-5516A-2GTXBP ϵÁУº628,808 Сʱ
TN-5516A-8PoE-2GTX ϵÁУº448,300 Сʱ
TN-5516A-8PoE-2GTXBP ϵÁУº439,442 Сʱ
±ê×¼ :Telcordia SR332

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÆÚ:5Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿