ºèÔ˹ú¼Ê

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú

NPort S9450IϵÁÐ

¼¯³ÉÍø¹ÜÐÍÒÔÌ«Íø½»Á÷»ú¹¦Ð§µÄ4¿ÚÎȹÌÐÍ×°±¸Ð§ÀÍÆ÷

  •  4 ¸ö RS-232/422/485 ´®¿Ú
  •  Ö§³Ö¶à´ï 5 ¸öÍø¹ÜÐÍÒÔÌ«Íø½»Á÷»ú¶Ë¿Ú£¨Ä³Ð©ÐͺÅÌṩ¹âÏ˶˿ڣ©
  •  Ö§³Ö DNP3 ºÍ Modbus ЭÒé
  •  ÇÐºÏ IEC 61850-3 ºÍ IEEE 1613£¨±äµçÕ¾£©±ê×¼
  •  Ö§³Ö Turbo Ring/Chain ºÍ RSTP/STP µÄÒÔÌ«ÍøÈßÓà
  •  Real COM/TTY Çý¶¯³ÌÐò£¬¿ÉÖ§³Ö Windows ºÍ Linux
  •  Ö§³Ö IEC 61850 MMS ЭÒé
  •  »ùÓÚ IEC 62443/NERC CIP µÄ±£»¤¹¦Ð§
  •  Ö§³Ö -40 ÖÁ 85¡ãC ¿íÎÂ
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú

NPort S9450I ϵÁÐ 4 ¶Ë¿Ú RS-232/422/485 ×°±¸ÁªÍøЧÀÍÆ÷ÄÚÖÃÈ«¹¦Ð§Íø¹ÜÐÍÒÔÌ«Íø½»Á÷»ú£¬×¨Îª±äµçÕ¾µÄÑÏ¿ÁÊÂÇéÇéÐζøÉè¼Æ¡£ÓÉÓÚ´ËϵÁвúƷͬʱ֧³Ö¹âÏ˶˿ںÍÒÔÌ«Íø¶Ë¿Ú£¬²¢¼¯×°±¸ÁªÍøЧÀÍÆ÷ºÍ½»Á÷»úÓÚÒ»Ì壬Óû§¿ÉÒÔÇáËÉ×°Öá¢ÖÎÀíºÍά»¤ NPort S9450I ÒÔ¼°ÅþÁ¬µÄ´®¿Ú×°±¸¡£

¸ßµç´Å¼æÈÝÐÔ£¬Ë³Ó¦ÑÏ¿ÁµÄ±äµçÕ¾ÇéÐÎ
NPort S9450I ϵÁÐÖ§³Ö¸ßˮƽµÄÀËÓ¿±£»¤¹¦Ð§£¬±ÜÃâ±äµçÕ¾ºÍ¹¤Òµ×Ô¶¯»¯Ó¦ÓÃÖг£¼ûµÄÀËÓ¿ºÍ EMI Ôì³ÉË𻵡£NPort S9450I Ö§³Ö -40 ÖÁ 85¡ãC ÊÂÇéζȺÍÅ䱸¶Æп¸ÖÍâ¿Ç£¬ÊÊÓÃÓÚÖÖÖÖ¹¤ÒµÇéÐΡ£
±ðµÄ£¬NPort S9450I µÄË«µçÔ´ÊäÈëͬʱÌṩÈßÓàºÍ¿í¹æÄ£µçѹÊäÈë¡£WV ÐͺÅÖ§³Ö 24/48 VDC µçÔ´ÊäÈ루18 ÖÁ 72 VDC£©£¬HV ÐͺÅÖ§³Ö 88 ÖÁ 300 VDC ºÍ 85 ÖÁ 264 VAC µçÔ´ÊäÈë¡£

Ö§³Ö IEC 61850 MMS ЭÒ飬ʵÏÖµçÁ¦ SCADA µÄ±ã½Ýά»¤
µçÁ¦ SCADA Ó¦ÓõÄÉú³¤Ç÷ÊÆÊǽÓÄÉ MMS ЭÒéͬʱ¿ØÖƲ¢¼àÊÓ IT ×°±¸£¨½»Á÷»ú¡¢Â·ÓÉÆ÷µÈ£©ºÍ IED£¨´«¸ÐÆ÷¡¢Öƶ¯Æ÷µÈ£©¡£ÕâÓë IT ×°±¸½ÓÄÉ SNMP ЭÒ飬IED ½ÓÄÉ MMS ЭÒéµÄ¹Å°åÖÎÀíÒªÁìÓкܴó²î±ð¡£ÊÂʵÉÏ£¬SI ÉõÖÁ¿ÉÄÜÐèÒªÖÎÀíÖÖÖÖʹÓÃרÓÐͨѶЭÒéµÄ¹Å°å×°±¸¡£
NPort S9450I ×°±¸ÁªÍøЧÀÍÆ÷ÊÇÈ«ÇòÊ׿ MMS ¼¯³Éµ½ IT ÐÍ×°±¸ÖеÄ×°±¸ÁªÍøЧÀÍÆ÷£¬×¨ÎªµçÁ¦ SCADA Ó¦ÓöøÉè¼Æ¡£ NPort S9450I »¹Ö§³ÖʹÓà MMS ¼àÊÓ S9450I Óë¹Å°å×°±¸Ö®¼äµÄ´®¿ÚͨѶ¡£

Ö§³Ö Modbus/DNP3 ЭÒéÍø¹Ø
NPort S9450I ϵÁÐΪ¼¯³ÉÖÖÖÖÀàÐͺ͹æÄ£µÄ¹¤Òµ Modbus/DNP3 ÍøÂçÌṩÁ˼«´óµÄÎÞаÐÔ¡£NPort S9450I Ö§³Ö½« Modbus TCP¡¢ASCII ºÍ RTU ×°±¸¼¯³Éµ½ÏÕЩÈκΠmaster/slave ģʽÖУ¬°üÀ¨´®¿ÚºÍÒÔÌ«ÍøͬΪ master µÄģʽ¡£
NPort S9450I ×°±¸ÁªÍøЧÀÍÆ÷»¹Ö§³Ö DNP3 ´®¿ÚºÍ DNP3 IP Ö®¼äµÄЭÒéת»»¡£ËùÓÐÐͺžù½ÓÄɽáʵÄÍÓÃÉè¼Æ£¬²¢Ö§³Öµ¼¹ìʽװÖá£


»ùÓÚ IEC 62443/NERC CIP µÄÍøÂç±£»¤¹¦Ð§
NPort S9450I ϵÁÐÌṩ»ùÓÚ IEC 62443/NERC CIP µÄÇå¾²¹¦Ð§£¬¿ÉÔöÇ¿ÍøÂçÇå¾²ÐÔ¡£¹¤Òµ×Ô¶¯»¯Ó¦Óó¤Ê±¼äµÄÍøÂçå´Ê±»úÔì³ÉÖØ´óËðʧ£¬Òò¶ø±£»¤Òªº¦Ê¹ÃüÍøÂçÃâÊÜÍøÂç¹¥»÷ÖÁ¹ØÖ÷Òª¡£

Ö§³Ö×°±¸¼¶»·ÍøÈßÓà
¹¤Òµ×Ô¶¯»¯µÄ×°±¸¼¶Í¨Ñ¶ÍøÂçºÜÊÇÒªº¦£¬ÓÉÓÚËüÃÇÓÃÓÚ¿ØÖƺͼà¿Ø×°±¸Àú³Ì¡£ÕâЩͨѶµÄ¿É¿¿ÐÔÈ¡¾öÓÚ×°±¸¼¶µÄ»·ÍøÈßÓ࣬»·ÍøÈßÓàÌṩ¿ìËÙÍøÂç¹ÊÕϼì²âºÍÖØÐÂÉèÖù¦Ð§£¬ÒÔÖ§³ÖÒªÇóÑÏ¿ÁµÄ¿ØÖÆÓ¦Óá£NPort S9450I ϵÁн« NPort ×°±¸ÁªÍøЧÀÍÆ÷µÄÈ«¹¦Ð§Ó빤ҵ½»Á÷»úÏ༯³É£¬¿ÉͬʱÔËÐд®¿Ú×°±¸ºÍÒÔÌ«Íø×°±¸¡£
±ðµÄ£¬NPort S9450I ϵÁл¹¿Éͨ¹ý±ê×¼ STP/RSTP ºÍ Moxa רÓÃµÄ Turbo Ring »ò Turbo Chain 2 ÖÖÈßÓàЭÒéʵÏÖ»·ÍøÈßÓà¡£Ò»Ì廯µÄÉè¼Æ£¬¿ÉÓÅ»¯ºÍ¼ò»¯ÄúµÄ×°±¸ÍøÂ磬²¢Ìá¸ß¿É¿¿ÐÔ¡£

ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ£º 
2£¬´¿µç×èÐÔ¸ºÔØ£º 1 A @ 24 VDC
Êý×ÖÊäÈëͨµÀ£º2
Êý×ÖÊäÈ룺 
+13 ÖÁ +30 V ÌåÏÖ״̬ 1
-30 ÖÁ +1 V ÌåÏÖ״̬ 0
ÊäÈëµçÁ÷£º8 mA

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100BaseT(X) ¶Ë¿Ú£¨RJ45 ÌÖÂÛ£©£º 
NPort S9450I£º5 ¸ö RJ45 ¶Ë¿Ú
100BaseFX ¶Ë¿Ú£¨¶àÄ£ SC ÌÖÂÛ£©£º 
NPort S9450I-2M-SC£º3 ¸ö RJ45 ¶Ë¿Ú£¬2 ¸ö¶àÄ£ SC ¶Ë¿Ú
100BaseFX ¶Ë¿Ú£¨¶àÄ£ ST ÌÖÂÛ£© £º
NPort S9450I-2M-ST£º3 ¸ö RJ45 ¶Ë¿Ú£¬2 ¸ö¶àÄ£ ST ¶Ë¿Ú
100BaseFX ¶Ë¿Ú£¨µ¥Ä£ SC ÌÖÂÛ£©£º 
NPort S9450I-2S-SC£º3 ¸ö RJ45 ¶Ë¿Ú£¬2 ¸öµ¥Ä£ SC ¶Ë¿Ú
100BaseFX ¶Ë¿Ú£¨µ¥Ä£ ST ÌÖÂÛ£© £º
NPort S9450I-2S-ST£º3 ¸ö RJ45 ¶Ë¿Ú£¬2 ¸öµ¥Ä£ ST ¶Ë¿Ú
µç´Å¸ôÀë±£»¤£º1.5 kV£¨ÄÚÖã©
¹âÏË
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±ê×¼£º 
IEEE 802.1D-2004£¬ÓÃÓÚÌìÉúÊ÷ЭÒé (STP)
IEEE 802.1p£¬ÓÃÓÚЧÀÍÆ·¼¶
IEEE 802.1Q£¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.1w£¬ÓÃÓÚ¿ìËÙÌìÉúÊ÷ЭÒé (RSTP)
IEEE 802.1X£¬ÓÃÓÚÊÚȨÈÏÖ¤
IEEE 802.3£¬ÓÃÓÚ 10BaseT
IEEE 802.3ad£¬ÓÃÓÚ LACP ¶Ë¿Ú¾ÛºÏ
IEEE 802.3u£¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IGMP ·Ö×飺256
VLAN ÊýÄ¿£º64
ÓÅÏȼ¶ÐÐÁУº4
VLAN ID ¹æÄ££ºVID 1 ÖÁ 4094

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÉèÖÃÑ¡Ï 
ͨ¹ý´®¿Ú/Telnet/SSH µÄÏÂÁîÐнçÃæ (CLI)£¬Web Console (HTTP/HTTPS)£¬Windows ÖÎÀí¹¤¾ß
ÖÎÀí £º
DHCP Client¡¢DHCP Option 82¡¢HTTP¡¢IEC 61850 MMS¡¢IPv4¡¢LLDP¡¢Port Mirror£¨¶Ë¿Ú¾µÏñ£©¡¢RARP¡¢RMON¡¢SMTP¡¢SNMPv1/v2c/v3¡¢Syslog¡¢Telnet¡¢TFTP¡¢Web Console
¹ýÂË£ºGMRP¡¢GVRP¡¢IGMP v1/v2
Windows Real COM Çý¶¯³ÌÐò£º 
Windows 95/98/ME/NT/2000¡¢Windows XP/2003/Vista/2008/7/8/8.1/10 (x86/x64)¡¢Windows 2008 R2/2012/2012 R2 (x64)¡¢Windows Embedded CE 5.0/6.0¡¢Windows XP Embedded
Linux Real TTY Çý¶¯³ÌÐò£ºÄں˰汾£º2.4.x¡¢2.6.x¡¢3.x¡¢4.x ºÍ 5.x
Fixed TTY Çý¶¯³ÌÐò £º
SCO UNIX¡¢SCO OpenServer¡¢UnixWare 7¡¢QNX 4.25¡¢QNX 6¡¢Solaris 10¡¢FreeBSD¡¢AIX 5.x¡¢HP-UX 11i¡¢Mac OS X
Android API£ºAndroid 3.1.x ¼°¸ü¸ß°æ±¾
¹¤ÒµÐ­Ò飺
Modbus TCP Server (Slave)¡¢DNP3 TCP Outstation
¶ÔʱЧÀÍ£ºNTP Server/Client£¬SNTP
MIB£º
Bridge MIB¡¢×°±¸ÉèÖà MIB¡¢Ethernet-like MIB¡¢MIB-II¡¢P-BRIDGE MIB¡¢Q-BRIDGE MIB¡¢RFC1213¡¢RFC1317¡¢RMON MIB Groups 1¡¢2¡¢3¡¢9¡¢RSTP MIB
ÈßÓàЭÒ飺 
RSTP¡¢Turbo Chain¡¢Turbo Ring v1¡¢Turbo Ring v2
ÍøÂçЭÒ飺 
HTTPS/SSL¡¢ÍâµØÕÊ»§¿É»á¼ûÐÔ¡¢TACACS+¡¢RADIUS¡¢SSH

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÌÖÂÛ£ºDB9 ¹«Í·
¶Ë¿ÚÊýÄ¿£º4
´®¿Ú±ê×¼£ºRS-232¡¢RS-422¡¢RS-485
²Ù×÷ģʽ £º
Real COM¡¢RFC2217¡¢TCP Client¡¢TCP Server¡¢UDP¡¢Modbus¡¢DNP3¡¢DNP3 Raw Socket¡¢½ûÓÃ
²¨ÌØÂÊ£º50 bps ÖÁ 921.6 kbps£¨Ö§³Ö·Ç±ê×¼²¨ÌØÂÊ£©
Êý¾Ýλ£º5¡¢6¡¢7¡¢8
×èֹλ£º1¡¢1.5¡¢2
УÑéλ£ºÎÞ¡¢Å¼¡¢Ææ¡¢Space¡¢Mark
Á÷Á¿¿ØÖÆ£ºÎÞ¡¢RTS/CTS¡¢XON/XOFF
¸ôÀë±£»¤£º2 kV
ÀËÓ¿±£»¤£º4 kV
RS-485 Êý¾ÝÁ÷Ïò¿ØÖÆ £ºADDC®£¨×Ô¶¯Êý¾ÝÆ«Ïò¿ØÖÆ£©
RS-485 ÉÏÀ­µç×è/ÏÂÀ­µç×裺1 k¦¸£¬150 k¦¸
RS-485 Öն˵ç×裺120 ¦¸
Console ¶Ë¿Ú£º
RS-232£¨TxD¡¢RxD¡¢GND£©£¬10-pin RJ45£¨19200¡¢n¡¢8¡¢1£©

´®¿ÚÐźÅ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
RS-232£º
TxD¡¢RxD¡¢RTS¡¢CTS¡¢DTR¡¢DSR¡¢DCD¡¢GND
RS-422£ºTx+¡¢Tx-¡¢Rx+¡¢Rx-¡¢GND
RS-485-4w£ºTx+¡¢Tx-¡¢Rx+¡¢Rx-¡¢GND
RS-485-2w£ºData+¡¢Data-¡¢GND

DIP ¿ª¹ØÉèÖÃ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÒÔÌ«Íø½Ó¿Ú£º 
Turbo Ring¡¢Master¡¢ñîºÏÆ÷¡¢Ô¤Áô

Modbus TCP

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Client ÅþÁ¬ÊýÄ¿£º32
Server ÅþÁ¬ÊýÄ¿£º16

DNP3£¨Í¸´«£©

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Master ÅþÁ¬ÊýÄ¿ £º16
Outstation ÅþÁ¬ÊýÄ¿£º32

µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
µçÔ´ÊäÈëÊýÄ¿£º2
µçÔ´ÌÖÂÛ£º1 ¸ö¿É²ðж 5 ´¥µã½ÓÏ߶Ë×Ó
·´½Ó±£»¤£ºÖ§³Ö
ÊäÈëµçÁ÷ £º
NPort S9450I-WV-T ϵÁУº520 mA @ 24 VDC
NPort S9450I-HV-T ϵÁУº80 mA @ 110 VDC
ÊäÈëµçѹ£º 
NPort S9450I-WV-T ϵÁУº24/48 VDC£¨18 ÖÁ 72 VDC£©
NPort S9450I-HV-T ϵÁУº110/220 VAC/VDC£¨85 ÖÁ 264 VAC ºÍ 88 ÖÁ 300 VDC£©

»úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Íâ¿Ç£º½ðÊô
³ß´ç£º80 x 160 x 109 mm£¨3.15 x 6.30 x 4.29 Ó¢´ç£©
ÖØÁ¿£º²úÆ·¾»ÖØ£º2.54 kg (5.60 lb)
×°Ö㺵¼¹ìʽװÖ㬱ڹÒʽװÖ㨴ø¿ÉÑ¡Ì×¼þ£©

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéÎÂ¶È £º-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£©£º-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È£º5 ÖÁ 95%£¨·ÇÀäÄý£©

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EMC£ºEN 61000-6-2/-6-4
EMI£ºCISPR 32£¬FCC Part 15B Class A
EMS£º 
IEC 61000-4-2 ESD£º½Ó´¥£º8 kV£»¿ÕÆø£º15 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º10 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º4 kV£»Ðźţº4 kV
IEC 61000-4-5 Surge£ºµçÔ´£º6 kV£»Ðźţº4 kV
IEC 61000-4-6 CS£º150 kHz ÖÁ 80 MHz£º10 V/m£»Ðźţº10 V/m
IEC 61000-4-8 PFMF
IEC 61000-4-11
ÇéÐβâÊÔ £º
IEC 60068-2-2
IEC 60068-2-14
±äµçÕ¾£ºIEC 61850-3£¬IEEE 1613
ΣÏÕÇéÐΣºUL/cUL Class I Division 2 Groups A/B/C/D
Safety£ºEN 61010-2-201£¬UL 61010-2-201
¹¥»÷£ºIEC 60068-2-27
Õñ¶¯£ºIEC 60068-2-6£¬IEC 60068-2-64

ÉùÃ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÂÌÉ«²úÆ·£ºRoHS¡¢CRoHS¡¢WEEE

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä£º347,436 Сʱ
±ê×¼£ºTelcordia SR332

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÏÞÆÚ£º5 Äê

OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿