ºèÔ˹ú¼Ê

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú

EDS-G516EϵÁÐ

16¿ÚȫǧÕ×Íø¹ÜÐÍÒÔÌ«Íø½»Á÷»ú

  • ¸ß´ï12¸ö10/100/1000BaseT(X)¿Ú¼°4¸ö100/1000BaseSFP¿Ú
  • Ö§³ÖTurbo Ring £¬Turbo Chain£¨×ÔÓúʱ¼ä < 50 ms @250̨½»Á÷»ú£© £¬RSTP/STP¼°MSTPÍøÂçÈßÓà¡£
  • RADIUS £¬TACACS+ £¬SNMPv3 £¬IEEE 802.1X £¬HTTPS £¬ºÍSSHÀ´ÔöÇ¿ÍøÂçSAFETY
  • ͨ¹ýÍøÂçä¯ÀÀÆ÷ £¬CLI £¬USB serial console £¬ABC-02-USB £¬MXconfig¼°Windowns utilityÇáËÉÖÎÀíÍøÂç
  • Ö§³ÖEtherNet/IP £¬PROFINET £¬¼°Modbus/TCPЭÒé £¬ÊÊÓÃÓÚ×°±¸ÖÎÀí¼°¼à¿Ø
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EDS-G516E ϵÁÐÅ䱸 16 ¸öǧÕ×ÒÔÌ«Íø¶Ë¿ÚºÍ¶à´ï 4 ¸ö¹âÏ˶˿Ú £¬ºÜÊÇÊÊÓÃÓÚ½«ÏÖÓÐÍøÂçÉý¼¶ÖÁǧÕ×ËÙÂÊ £¬»òÕß¹¹½¨ÐµÄȫǧÕ×Ö÷¸ÉÍøÂ硣ǧÕ×´«ÊäËÙÂÊÌá¸ßÁË´ø¿í £¬ÊµÏÖ¸ßÐÔÄÜÍøÂç¿ìËÙ´«Êä´ó×ÚÊÓƵ¡¢ÓïÒôºÍÊý¾Ý¡£

Turbo Ring¡¢Turbo Chain¡¢RSTP/STP ºÍ MSTP µÈÒÔÌ«ÍøÈßÓàÊÖÒÕ £¬ÔöÇ¿ÁËϵͳ¿É¿¿ÐÔºÍÖ÷¸ÉÍøÂç¿ÉÓÃÐÔ¡£EDS-G516E ϵÁÐרΪÑÏ¿ÁÒªÇóµÄͨѶӦÓöøÉè¼Æ £¬ÀýÈ磺ÊÓƵºÍÀú³Ì¼à¿Ø¡¢ITS ºÍ DCS ϵͳ £¬ÕâЩӦÓþù¿ÉÊÜÒæÓÚ¿ÉÀ©Õ¹µÄÖ÷¸ÉͨѶÍøÂç¡£

ÆäËûÌصãºÍÓÅÊÆ
?ÏÂÁîÐнçÃæ (CLI) £¬¿É¿ìËÙÉèÖÃÖ÷ÒªÖÎÀí¹¦Ð§
?DHCP Option 82 £¬ÓÃÓÚ²î±ðÕ½ÂÔ·ÖÅÉ IP µØµã
?Ö§³Ö EtherNet/IP¡¢PROFINET ºÍ Modbus TCP ЭÒé×°±¸ÖÎÀíºÍ¼à¿Ø
?IGMP snooping ºÍ GMRP £¬ÓÃÓÚ¹ýÂË×é²¥Á÷Á¿
?»ùÓÚ¶Ë¿ÚµÄ VLAN¡¢IEEE 802.1Q VLAN ºÍ GVRP £¬¿É¼ò»¯ÍøÂçÍýÏë
?Ö§³Ö ABC-02-USB£¨×Ô¶¯±¸·ÝÉèÖÃÆ÷£© £¬ÓÃÓÚϵͳÉèÖñ¸·Ý/»Ö¸´ºÍ¹Ì¼þÉý¼¶
?QoS£¨IEEE 802.1p/1Q ºÍ TOS/DiffServ£©Ìá¸ßÁËÍøÂçÎȹÌÐÔ
?¶Ë¿Ú¾ÛºÏ £¬¿ÉÓÅ»¯ÍøÂç´ø¿í
?RADIUS¡¢TACACS+¡¢MAB ÊÚȨÈÏÖ¤¡¢SNMPv3¡¢IEEE 802.1x¡¢MAC ACL¡¢HTTPS¡¢SSH ºÍ Sticky MAC µØµã £¬ÓÃÓÚÔöÇ¿ÍøÂçSAFETY
?SNMPv1/v2c/v3 Ö§³Ö²î±ð¼¶±ðµÄÍøÂçÖÎÀí
?RMON Ö§³Ö×Ô¶¯ÍøÂç¼à¿Ø
?´ø¿íÖÎÀí £¬¿ÉÔ¤·À·ºÆð²»Îȹ̵ÄÍøÂç״̬
?»ùÓÚ MAC µØµãµÄ¶Ë¿ÚËø¶¨¹¦Ð§ £¬±ÜÃâδ¾­ÊÚȨµÄ»á¼û
?Ö§³Ö¶Ë¿Ú¾µÏñ¹¦Ð§ £¬±ãÓÚÔÚÏßµ÷ÊÔ
?ͨ¹ýµç×ÓÓʼþºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯·¢³öÒì³£ÖÒÑÔ

ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ :1 £¬´¿µç×èÐÔ¸ºÔØ£º1 A @ 24 VDC
°´Å¥ :¸´Î»°´Å¥
Êý×ÖÊäÈëͨµÀ :1
Êý×ÖÊäÈë 
+13 ÖÁ +30 V ÌåÏÖ״̬ 1
-30 ÖÁ +3 V ÌåÏÖ״̬ 0
ÊäÈëµçÁ÷£¨max£©£º8 mA

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100/1000BaseT(X) ¶Ë¿Ú£¨RJ45 ÌÖÂÛ£© :
12
ËÙÂÊ×Ô˳Ӧ
È«/°ëË«¹¤Ä£Ê½
×Ô¶¯ MDI/MDI-X ÅþÁ¬
100/1000BaseSFP ²å²Û :4
±ê×¼ :
IEEE 802.3 £¬ÓÃÓÚ 10BaseT
IEEE 802.3u £¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX
IEEE 802.3ab £¬ÓÃÓÚ 1000BaseT(X)
IEEE 802.3z £¬ÓÃÓÚ 1000BaseSX/LX/LHX/ZX
IEEE 802.3x £¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.1D-2004 £¬ÓÃÓÚÌìÉúÊ÷ЭÒé (STP)
IEEE 802.1w £¬ÓÃÓÚ¿ìËÙÌìÉúÊ÷ЭÒé (RSTP)
IEEE 802.1s £¬ÓÃÓÚ¶àÌìÉúÊ÷ЭÒé (MSTP)
IEEE 802.1p £¬ÓÃÓÚЧÀÍÆ·¼¶
IEEE 802.1Q £¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.1X £¬ÓÃÓÚÊÚȨÈÏÖ¤
IEEE 802.3ad £¬ÓÃÓÚ LACP ¶Ë¿Ú¾ÛºÏ

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¹ýÂË :802.1Q VLAN¡¢»ùÓÚ¶Ë¿ÚµÄ VLAN¡¢GVRP¡¢IGMP v1/v2/v3¡¢GMRP
¹¤ÒµÐ­Òé :EtherNet/IP¡¢Modbus TCP¡¢PROFINET IO Device (Slave)
ÖÎÀí :
LLDP¡¢Back Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢BOOTP¡¢Port Mirror£¨¶Ë¿Ú¾µÏñ£©¡¢DHCP Option 66/67/82¡¢DHCP Server/Client¡¢Fiber check¡¢Flow control£¨Á÷Á¿¿ØÖÆ£©¡¢IPv4/IPv6¡¢RARP¡¢RMON¡¢SMTP¡¢SNMP Inform¡¢SNMPv1/v2c/v3¡¢Syslog¡¢Telnet¡¢TFTP 
MIB :Ethernet-like MIB¡¢MIB-II¡¢Bridge MIB¡¢P-BRIDGE MIB¡¢Q-BRIDGE MIB¡¢RMON MIB Groups 1, 2, 3, 9, RSTP MIB
ÈßÓàЭÒé :Á´Â·¾ÛºÏ¡¢MSTP¡¢RSTP¡¢STP¡¢Turbo Chain¡¢Turbo Ring v1/v2
SAFETY :¹ã²¥·ç±©±£»¤¡¢HTTPS/SSL¡¢TACACS+¡¢SNMPv3¡¢MAB ÊÚȨÈÏÖ¤¡¢Sticky MAC¡¢NTP ÊÚȨÈÏÖ¤¡¢MAC ACL¡¢¶Ë¿ÚËø¶¨¡¢RADIUS¡¢SSH¡¢½ÓÄÉ TLS µÄ SMTP
¶ÔʱЧÀÍ :NTP Server/Client¡¢SNTP

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IGMP ·Ö×é :2048
¾ÞÐÍÖ¡¾Þϸ :9.6 KB
MAC µØµã±í¾Þϸ :8 K
VLAN ÊýÄ¿£¨max£© :256
Êý¾Ý°ü»º³åÇø¾Þϸ :4 Mb
ÓÅÏȼ¶ÐÐÁÐ :4
VLAN ID ¹æÄ£ :VID 1 ÖÁ 4094

USB ½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
´æ´¢¶Ë¿Ú :USB Type A

LED ½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
LED ָʾµÆ :PWR1¡¢PWR2¡¢STATE¡¢FAULT¡¢10/100M£¨TP ¶Ë¿Ú£©¡¢1000M£¨TP ¶Ë¿Ú£©¡¢100/1000M£¨SFP ¶Ë¿Ú£©¡¢MSTR/HEAD¡¢CPLR/TAIL

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú :USB ´®¿Ú console£¨Type B ÌÖÂÛ£©

DIP ¿ª¹ØÉèÖÃ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
DIP ¿ª¹Ø :Turbo Ring¡¢Master¡¢ñîºÏÆ÷¡¢Ô¤Áô

µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÅþÁ¬ :2 ¸ö¿É²ðж 4 ´¥µã½ÓÏ߶Ë×Ó
ÊäÈëµçÁ÷ :0.39 A @ 24 VDC
ÊäÈëµçѹ :12/24/48/-48 VDC £¬ÈßÓàË«µçÔ´ÊäÈë
ÊÂÇéµçѹ :9.6 ÖÁ 60 VDC
¹ýÔصçÁ÷±£»¤ :Ö§³Ö
·´½Ó±£»¤ :Ö§³Ö

»úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Íâ¿Ç :½ðÊô
IP Æ·¼¶ :IP30
³ß´ç :79.2 x 135 x 137 mm£¨3.1 x 5.3 x 5.4 Ó¢´ç£©
ÖØÁ¿ :1440 g (3.18 lb)
×°Öà :µ¼¹ìʽװÖà £¬±Ú¹ÒʽװÖ㨴ø¿ÉÑ¡Ì×¼þ£©

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéÎÂ¶È :
EDS-G516E-4GSFP£º-10 ÖÁ 60¡ãC£¨14 ÖÁ 140¡ãF£©
EDS-G516E-4GSFP-T£º-40 ÖÁ 75¡ãC£¨-40 ÖÁ 167¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£© :-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È :5 ÖÁ 95%£¨·ÇÀäÄý£©

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
SAFETY :UL 508
EMC :EN 61000-6-2/-6-4
EMI :CISPR 32 £¬FCC Part 15B Class A
EMS :
IEC 61000-4-2 ESD£º½Ó´¥£º8 kV£»¿ÕÆø£º15 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º10 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º4 kV£»Ðźţº4 kV
IEC 61000-4-5 Surge£ºµçÔ´£º4 kV£»Ðźţº4 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8 PFMF
ΣÏÕÇéÐÎ :ATEX £¬Class I Division 2
º£Ê :DNV-GL¡¢LR¡¢ABS¡¢NK
±äµçÕ¾ £ºIEC 61850-3 £¬IEEE 1613
¹ìµÀ½»Í¨ £ºEN 50121-4
½»Í¨¿ØÖÆ £ºNEMA TS2
¹¥»÷ £ºIEC 60068-2-27
×ÔÓÉÂäÌå £ºIEC 60068-2-32
Õñ¶¯ £ºIEC 60068-2-6

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä £º805,491 Сʱ
±ê×¼ £ºTelcordia (Bellcore) £¬GB

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÏÞÆÚ £º5 Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿