EDS-508AϵÁÐ

8¿ÚÍø¹ÜÐÍÈßÓàÒÔÌ«Íø½»Á÷»ú

  • Ö§³ÖTurbo Ring£¬Turbo Chain£¬RSTP/STPºÍMSTPÓÃÓÚÒÔÌ«ÍøÈßÓà
  • TACACS+£¬SNMPv3£¬IEEE 802.1X£¬HTTPSºÍSSHÀ´ÔöÇ¿ÍøÂçSAFETY
  • ͨ¹ýÍøÒ³ä¯ÀÀÆ÷£¬Telnet/Serial console£¬CLI£¬Windows utilityºÍABC-01ÇáËÉÖÎÀíÍøÂç
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EDS-508A 8 ¶Ë¿ÚÍø¹ÜÐ͹¤ÒµÒÔÌ«Íø½»Á÷»ú½ÓÄÉÏȽøµÄ Turbo Ring ºÍ Turbo Chain£¨×ÔÓúʱ¼ä < 20 ms£©£¬RSTP/STP ºÍ MSTP ÍøÂçÈßÓàÊÖÒÕ£¬ÔöÇ¿ÁËϵͳ¿É¿¿ÐÔºÍÖ÷¸ÉÍøÂç¿ÉÓÃÐÔ¡£Õâ¿î²úÆ·Ö§³Ö -40 ÖÁ 75¡ãC ¿íÎÂÐͺÅ£¬EDS-508A ½»Á÷»ú»¹Å䱸ÏȽøµÄÖÎÀí¹¦Ð§£¬ÊÊÓÃÓÚÈκÎÑÏ¿ÁµÄ¹¤ÒµÇéÐΡ£

ÆäËûÌصãºÍÓÅÊÆ
?ÏÂÁîÐнçÃæ (CLI)£¬¿É¿ìËÙÉèÖÃÖ÷ÒªÖÎÀí¹¦Ð§
?DHCP Option 82£¬ÓÃÓÚ²î±ðÕ½ÂÔ·ÖÅÉ IP µØµã
?Ö§³Ö EtherNet/IP ºÍ Modbus TCP ЭÒéµÄ×°±¸ÖÎÀíºÍ¼à¿Ø
?¼æÈÝ PROFINET ЭÒ飬¿ÉʵÏÖ͸Ã÷Êý¾Ý´«Êä
?ͨ¹ýµç×ÓÓʼþºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯·¢³öÒì³£ÖÒÑÔ
?IGMP snooping ºÍ GMRP£¬ÓÃÓÚ¹ýÂË×é²¥Á÷Á¿
?»ùÓÚ¶Ë¿ÚµÄ VLAN¡¢IEEE 802.1Q VLAN ºÍ GVRP£¬¿É¼ò»¯ÍøÂçÍýÏë
?QoS£¨IEEE 802.1p/1Q ºÍ TOS/DiffServ£©Ìá¸ßÁËÍøÂçÎȹÌÐÔ
?¶Ë¿Ú¾ÛºÏ£¬¿ÉÓÅ»¯ÍøÂç´ø¿í
?RMON Ö§³Ö×Ô¶¯ÍøÂç¼à¿Ø
?SNMPv1/v2c/v3 Ö§³Ö²î±ð¼¶±ðµÄÍøÂçÖÎÀí
?´ø¿íÖÎÀí£¬¿ÉÔ¤·À·ºÆð²»Îȹ̵ÄÍøÂç״̬
?»ùÓÚ MAC µØµãµÄ¶Ë¿ÚËø¶¨¹¦Ð§£¬±ÜÃâδ¾­ÊÚȨµÄ»á¼û

ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ £º2£¬´¿µç×èÐÔ¸ºÔØ£º1 A @ 24 VDC
Êý×ÖÊäÈëͨµÀ £º2
Êý×ÖÊäÈë £º
+13 ÖÁ +30 V ÌåÏÖ״̬ 1
-30 ÖÁ +3 V ÌåÏÖ״̬ 0
ÊäÈëµçÁ÷£¨max£©£º8 mA
°´Å¥ £º¸´Î»°´Å¥

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100BaseT(X) ¶Ë¿Ú£¨RJ45 ÌÖÂÛ£© £º
EDS-508A ϵÁУº8
EDS-508A-MM/SS ϵÁУº6

ËùÓÐÐͺžùÖ§³Ö£º
ËÙÂÊ×Ô˳Ӧ
È«/°ëË«¹¤Ä£Ê½
×Ô¶¯ MDI/MDI-X ÅþÁ¬
100BaseFX ¶Ë¿Ú£¨¶àÄ£ SC ÌÖÂÛ£© £ºEDS-508A-MM-SC ϵÁУº2
100BaseFX ¶Ë¿Ú£¨¶àÄ£ ST ÌÖÂÛ£© £ºEDS-508A-MM-ST ϵÁУº2
100BaseFX ¶Ë¿Ú£¨µ¥Ä£ SC ÌÖÂÛ£© £ºEDS-508A-SS-SC ϵÁУº2
100BaseFX ¶Ë¿Ú£¬µ¥Ä£ SC ÌÖÂÛ£¬80 km £ºEDS-508A-SS-SC-80 ϵÁУº2
±ê×¼ £º
IEEE 802.3£¬ÓÃÓÚ 10BaseT
IEEE 802.3u£¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX
IEEE 802.1X£¬ÓÃÓÚÊÚȨÈÏÖ¤
IEEE 802.1D-2004£¬ÓÃÓÚÌìÉúÊ÷ЭÒé (STP)
IEEE 802.1w£¬ÓÃÓÚ¿ìËÙÌìÉúÊ÷ЭÒé (RSTP)
IEEE 802.1s£¬ÓÃÓÚ¶àÌìÉúÊ÷ЭÒé (MSTP)
IEEE 802.1Q£¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.1p£¬ÓÃÓÚЧÀÍÆ·¼¶
IEEE 802.3x£¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.3ad£¬ÓÃÓÚ LACP ¶Ë¿Ú¾ÛºÏ
¹âÏË£º
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¹ýÂË £º802.1Q VLAN¡¢»ùÓÚ¶Ë¿ÚµÄ VLAN¡¢IGMP v1/v2¡¢GVRP¡¢GMRP
¹¤ÒµÐ­Òé £ºEtherNet/IP¡¢Modbus TCP
ÖÎÀí £ºIPv4/IPv6¡¢SNMPv1/v2c/v3¡¢LLDP¡¢Port Mirror£¨¶Ë¿Ú¾µÏñ£©¡¢Back Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢BOOTP¡¢DDM¡¢DHCP Option 66/67/82¡¢DHCP Server/Client¡¢Fiber check¡¢Flow control£¨Á÷Á¿¿ØÖÆ£©¡¢RARP¡¢RMON¡¢SMTP¡¢SNMP Inform¡¢Syslog¡¢Telnet¡¢TFTP 
MIB £º
MIB-II¡¢Bridge MIB¡¢Ethernet-like MIB¡¢P-BRIDGE MIB¡¢Q-BRIDGE MIB¡¢RMON MIB Groups 1, 2, 3, 9, RSTP MIB
ÈßÓàЭÒé £ºSTP¡¢MSTP¡¢RSTP¡¢LACP¡¢Á´Â·¾ÛºÏ¡¢Turbo Chain¡¢Turbo Ring v1/v2
SAFETY £ºHTTPS/SSL¡¢TACACS+¡¢¶Ë¿ÚËø¶¨¡¢RADIUS¡¢SSH
¶ÔʱЧÀÍ £ºNTP Server/Client¡¢SNTP¡¢IEEE 1588v2 PTP£¨»ùÓÚÈí¼þ£©

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IGMP ·Ö×é £º256
MAC µØµã±í¾Þϸ £º8 K
VLAN ÊýÄ¿£¨max£© £º64
Êý¾Ý°ü»º³åÇø¾Þϸ £º1 Mb
ÓÅÏȼ¶ÐÐÁÐ £º4
VLAN ID ¹æÄ£ £ºVID 1 ÖÁ 4094

LED ½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
LED ָʾµÆ £ºPWR1¡¢PWR2¡¢FAULT¡¢10/100M£¨TP ¶Ë¿Ú£©¡¢100M£¨¹âÏ˶˿ڣ©¡¢MSTR/HEAD¡¢CPLR/TAIL

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú £ºRS-232£¨TxD¡¢RxD¡¢GND£©£¬8-pin RJ45£¨115200¡¢n¡¢8¡¢1£©

DIP ¿ª¹ØÉèÖÃ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÒÔÌ«Íø½Ó¿Ú £ºTurbo Ring¡¢Master¡¢ñîºÏÆ÷¡¢Ô¤Áô

µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÅþÁ¬ £º2 ¸ö¿É²ðж 6 ´¥µã½ÓÏ߶Ë×Ó
ÊäÈëµçѹ £º12/24/48 VDC£¬ÈßÓàË«µçÔ´ÊäÈë
ÊÂÇéµçѹ £º9.6 ÖÁ 60 VDC
ÊäÈëµçÁ÷ £º
EDS-508A ϵÁУº0.22 A @ 24 VDC
EDS-508A-MM/SS ϵÁУº0.30 A @ 24 VDC
¹ýÔصçÁ÷±£»¤ £ºÖ§³Ö
·´½Ó±£»¤ £ºÖ§³Ö

»úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Íâ¿Ç £º½ðÊô
IP Æ·¼¶ £ºIP30
³ß´ç £º
80.2 x 135 x 105 mm£¨3.16 x 5.31 x 4.13 Ó¢´ç£©
ÖØÁ¿ £º1040 g (2.3 lb)
×°Öà £ºµ¼¹ìʽװÖ㬱ڹÒʽװÖ㨴ø¿ÉÑ¡Ì×¼þ£©

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéÎÂ¶È £º
±ê×¼Ðͺţº-10 ÖÁ 60¡ãC£¨14 ÖÁ 140¡ãF£©
¿íÎÂÐͺţº-40 ÖÁ 75¡ãC£¨-40 ÖÁ 167¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£© £º-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È £º5 ÖÁ 95%£¨·ÇÀäÄý£©

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
SAFETY £ºEN 60950-1¡¢UL 60950-1¡¢CSA C22.2 ±àºÅ 60950-1¡¢UL 508
ΣÏÕÇéÐÎ £ºATEX£¬Class I Division 2
EMC £ºEN 55032/24
EMI £ºCISPR 32£¬FCC Part 15B Class A
EMS £º
IEC 61000-4-2 ESD£º½Ó´¥£º6 kV£»¿ÕÆø£º8 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º20 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º2 kV£»Ðźţº1 kV
IEC 61000-4-5 Surge£ºµçÔ´£º2 kV£»Ðźţº2 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8 PFMF
¹¥»÷ £ºIEC 60068-2-27
Õñ¶¯ £ºIEC 60068-2-6
×ÔÓÉÂäÌå £ºIEC 60068-2-31

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä £º1,043,909 Сʱ
±ê×¼ £ºTelcordia (Bellcore)£¬GB

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÏÞÆÚ £º5 Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿