ºèÔ˹ú¼Ê

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú

PT-508ϵÁÐ

IEC 61850-3 8¿ÚÍø¹ÜÐ͵¼¹ìʽÒÔÌ«Íø½»Á÷»ú

  • ÇÐºÏ IEC 61850-3 ºÍ IEEE 1613 ±ê×¼
  • Ö§³Ö Turbo Ring ºÍ Turbo Chain£¨×ÔÓúʱ¼ä < 20 ms @ 250 ̨½»Á÷»ú£©£¬ÒÔ¼° RSTP/STP/MSTP ÍøÂçÈßÓà
  • ͨ¹ý Web ä¯ÀÀÆ÷¡¢CLI¡¢Telnet/´®¿Ú console¡¢Windows ÖÎÀí¹¤¾ßºÍ ABC-01 ÇáËÉÖÎÀíÍøÂç
  • ͨÓà 24/48 VDC ¸ôÀëÈßÓàË«µçÔ´ÊäÈë
  • 110/220 VDC/VAC ¿íµçÔ´¹æÄ£
  • Ö§³Ö Modbus TCP¡¢LLDP¡¢SNMP Inform¡¢QoS¡¢IGMP snooping¡¢VLAN¡¢IEEE 802.1X¡¢HTTPS¡¢SNMPv3 ºÍ SSH
  • Ö§³Ö -40 ÖÁ 85¡ãC ÊÂÇéζÈ
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
PowerTrans PT-508 רΪ֪×ã±äµçÕ¾×Ô¶¯»¯ÏµÍ³ÐèÇó¶øÉè¼Æ£¨IEC 61850-3¡¢IEEE 1613£©¡£PT-508 Ö§³Ö¹âÏË¿ìËÙÒÔÌ«ÍøÖ÷¸ÉÍøÂç¡¢ÈßÓà»·Íø¡¢ÈßÓàµçÔ´ÊäÈ루24 VDC »ò 48 VDC£©ºÍ´ø¸ôÀë±£»¤µÄµçÔ´ÊäÈ루24 VDC¡¢48 VDC »ò 110/220 VDC/VAC£©£¬¿ÉÌá¸ßͨѶÎȹÌÐÔ£¬²¢¿É½ÚÔ¼²¼Ïß/½ÓÏß±¾Ç®¡£±ðµÄ£¬PT-508 ½»Á÷»ú½ÓÄɵĵ¼¹ìʽºÍ±Ú¹ÒʽÉè¼Æ£¬¿É¼ò»¯ÍøÂçÍýÏëÀú³Ì£¬¶à¿ÉΪÅäµçÓ¦ÓÃ×°Öà 8 ¸ö°ÙÕ×ÒÔÌ«Íø¶Ë¿Ú£¬Ìṩ¸ü´óµÄÎÞаÐÔ¡£

ÆäËûÌصãºÍÓÅÊÆ
? ÏÂÁîÐнçÃæ (CLI)£¬¿É¿ìËÙÉèÖÃÖ÷ÒªÖÎÀí¹¦Ð§
? VLAN Unaware£ºÖ§³ÖÓÉÌض¨ IED ÎüÊÕµÄÓÅÏȼ¶±ê¼ÇÖ¡
? Ö§³Ö EtherNet/IP ºÍ Modbus TCP ¹¤ÒµÒÔÌ«ÍøЭÒé
? ͨ¹ý Web ä¯ÀÀÆ÷¡¢Telnet/´®¿Ú Console¡¢CLI¡¢Windows ÖÎÀí¹¤¾ßºÍ ABC-01 ×Ô¶¯±¸·ÝÉèÖÃÆ÷¾ÙÐÐÉèÖÃ
? DHCP Option 82£¬ÓÃÓÚ²î±ðÕ½ÂÔ·ÖÅÉ IP µØµã
? IGMP snooping ºÍ GMRP£¬ÓÃÓÚ¹ýÂ˹¤ÒµÒÔÌ«ÍøЭÒéµÄ×é²¥Á÷Á¿
? IEEE 802.3ad¡¢LACP£¬¿ÉÓÅ»¯ÍøÂç´ø¿í
? ´ø¿íÖÎÀí£¬¿ÉÔ¤·À·ºÆð²»Îȹ̵ÄÍøÂç״̬
? Ö§³Ö¶Ë¿Ú¾µÏñ¹¦Ð§£¬±ãÓÚÔÚÏßµ÷ÊÔ
? ͨ¹ýµç×ÓÓʼþºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯·¢³öÒì³£ÖÒÑÔ
? RMON Ö§³Ö×Ô¶¯µÄÍøÂç¼à¿Ø
? ×Ô¶¯»Ö¸´ÔÚÏß×°±¸µÄ IP µØµã
? ¿ìËÙ»»Ï߻ָ´

ÍøÂçsafetyÌØÕ÷
? Óû§ÃÜÂë¶à²ãsafety±£»¤£¬±ÜÃâδ¾­ÊÚȨ¾ÙÐÐÉèÖÃ
? SSH/HTTPS ÓÃÓÚÃÜÂëºÍÊý¾Ý¼ÓÃÜ
? ʹÓûùÓÚ 802.1X ¶Ë¿ÚµÄÍøÂç»á¼û¿ØÖÆËø¶¨½»Á÷»ú¶Ë¿Ú£¬Ö»ÓÐÊÚȨ¿Í»§ÄÜ»á¼û¸Ã¶Ë¿Ú
? RADIUS/TACACS+ ÔÊÐí´ÓÖпØÊÒÖÎÀíÃÜÂë
? 802.1Q VLAN ÔÊÐí¶ÔËùÑ¡¶¨µÄ½»Á÷»ú¶Ë¿Ú¼ä£¬¾ÙÐÐÁ÷Á¿´«ÊäµÄÂß¼­·ÖÅÉ
? ±£»¤½»Á÷»ú¶Ë¿Ú£¬Ö»ÔÊÐíÌض¨×°±¸ºÍ/»ò MAC µØµã»á¼û¸Ã¶Ë¿Ú
? ¹Ø±ÕÒ»¸ö»ò¶à¸ö¶Ë¿ÚÒÔ×èÖ¹ÍøÂçÁ÷Á¿
? SNMPv3 Ìṩ¼ÓÃÜÊÚȨºÍsafety»á¼û

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100BaseT(X) ¶Ë¿Ú£¨RJ45 ÌÖÂÛ£© £º6
100BaseFX ¶Ë¿Ú£¨¶àÄ£ SC ÌÖÂÛ£© £ºPT-508-MM-SC ϵÁУº 2
100BaseFX ¶Ë¿Ú£¨¶àÄ£ ST ÌÖÂÛ£© £ºPT-508-MM-ST ϵÁУº2
100BaseFX ¶Ë¿Ú£¨µ¥Ä£ SC ÌÖÂÛ£© £ºPT-508-SS-SC ϵÁУº2
100BaseFX ¶Ë¿Ú£¨¶àÄ£ LC ÌÖÂÛ£© £ºPT-508-MM-LC ϵÁУº2
100BaseFX ¶Ë¿Ú£¨µ¥Ä£ LC ÌÖÂÛ£© £ºPT-508-SS-LC ϵÁУº2
 
¹âÏË 
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±ê×¼ £º
IEEE 802.1D-2004£¬ÓÃÓÚÌìÉúÊ÷ЭÒé (STP)
IEEE 802.1p£¬ÓÃÓÚЧÀÍÆ·¼¶
IEEE 802.1Q£¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.1s£¬ÓÃÓÚ¶àÌìÉúÊ÷ЭÒé (MSTP)
IEEE 802.1w£¬ÓÃÓÚ¿ìËÙÌìÉúÊ÷ЭÒé (RSTP)
IEEE 802.1X£¬ÓÃÓÚÊÚȨÈÏÖ¤
IEEE 802.3£¬ÓÃÓÚ 10BaseT
IEEE 802.3ab£¬ÓÃÓÚ 1000BaseT(X)
IEEE 802.3ad£¬ÓÃÓÚ LACP ¶Ë¿Ú¾ÛºÏ
IEEE 802.3u£¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX
IEEE 802.3x£¬ÓÃÓÚÁ÷Á¿¿ØÖÆ

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
¹ýÂË £º802.1Q¡¢GMRP¡¢GVRP¡¢IGMP v1/v2¡¢»ùÓÚ¶Ë¿ÚµÄ VLAN ºÍ VLAN unaware
¹¤ÒµÐ­Ò飺EtherNet/IP¡¢Modbus TCP
ÖÎÀí £ºBack Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢BOOTP¡¢DHCP Option 66/67/82¡¢DHCP Server/Client¡¢Flow control£¨Á÷Á¿¿ØÖÆ£©¡¢HTTP¡¢IPv4/IPv6¡¢LLDP¡¢Port Mirror£¨¶Ë¿Ú¾µÏñ£©¡¢RARP¡¢RMON¡¢SMTP¡¢SNMP Inform¡¢SNMPv1/v2c/v3¡¢Syslog¡¢Telnet¡¢TFTP
MIB £ºBridge MIB¡¢Ethernet-like MIB¡¢MIB-II¡¢P-BRIDGE MIB¡¢Q-BRIDGE MIB¡¢RMON MIB Groups 1¡¢2¡¢3¡¢9¡¢RSTP MIB
ÈßÓàЭÒ飺Á´Â·¾ÛºÏ¡¢MSTP¡¢RSTP¡¢STP¡¢Turbo Chain¡¢Turbo Ring v1/v2
safety £ºHTTPS/SSL¡¢TACACS+¡¢¶Ë¿ÚËø¶¨¡¢RADIUS¡¢ËÙÂÊÏÞÖÆ¡¢SSH
¶ÔʱЧÀÍ£ºNTP Server/Client¡¢SNTP¡¢100BaseFX µ¥Ä£

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IGMP ·Ö×é £º256
MAC µØµã±í´óС£º8 K
Max VLAN ÊýÄ¿ £º64
Êý¾Ý°ü»º³åÇø¾Þϸ £º1 Mb
VLAN ID ¹æÄ£ £ºVID 1 ÖÁ 4094
ÓÅÏȼ¶ÐÐÁÐ £º4

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú £ºRS-232 (RJ45)

ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ £º´¿µç×èÐÔ¸ºÔØ£º1 A @ 24 VDC

 µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÅþÁ¬ £º1 ¸ö¿É²ðж 5 ´¥µã½ÓÏ߶Ë×Ó
ÊäÈëµçѹ £º
PT-508-24/48 ϵÁУºÈßÓàË«µçÔ´ÊäÈë
PT-508-24 ϵÁУº24 VDC£¨18 ÖÁ 36 VDC£©
PT-508-48 ϵÁУº48 VDC£¨36 ÖÁ 72 VDC£©
PT-508--HV ϵÁУº110/220 VAC/VDC£¨88 ÖÁ 300 VAC£¬85 ÖÁ 264 VDC£©
¹ýÔصçÁ÷±£»¤£ºÖ§³Ö
·´½Ó±£»¤ £ºÖ§³Ö
ÊäÈëµçÁ÷ £º
PT-508-24 ϵÁУº0.27 A @ 24 VDC
PT-508-48 ϵÁУº0.12 A @ 48 VDC
PT-508-HV ϵÁУº0.18/0.11 A @ 110/220 VAC£¬0.084/0.043 A @ 110/220 VDC

»úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Íâ¿Ç £ºÂÁ
IP Æ·¼¶£ºIP40
³ß´ç£¨ÎÞ¹Ò¶ú£©£º60 x 160 x 110 mm£¨2.36 x 6.30 x 4.33 Ó¢´ç£©
ÖØÁ¿ £º995 g (2.21 lb)
×°Öà £ºµ¼¹ìʽװÖᢵ¼¹ìʽװÖ㨴ø¿ÉÑ¡Ì×¼þ£©

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéζȣº-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
×¢ÖØ£ºÀäÆô¶¯ÒªÇóÖÁÉÙ 100 VAC @ -40¡ãC
´æ´¢Î¶ȣ¨º¬°ü×°£© £º-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È £º5 ÖÁ 95%£¨·ÇÀäÄý£©

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
EMI £ºEN 55032 Class A¡¢CISPR 32¡¢FCC Part 15B Class A
EMS £º
IEC 61000-4-2 ESD£º½Ó´¥£º8 kV£»¿ÕÆø£º15 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º20 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º4 kV£»Ðźţº4 kV
IEC 61000-4-5 Surge£ºµçÔ´£º4 kV£»Ðźţº4 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8 PFMF
IEC 61000-4-11
±äµçÕ¾ £ºIEC 61850-3£¬IEEE 1613
safety £ºUL 508

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä £º394,238 Сʱ
±ê×¼ £ºTelcordia SR332

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÆÚ:5Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿