ºèÔ˹ú¼Ê

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú

IKS-6726AϵÁÐ

24+2G¿ÚÄ£¿é»¯Íø¹ÜÐÍÒÔÌ«Íø½»Á÷»ú

  • 2 ¸öǧÕ×ºÍ 24 ¸ö°ÙÕ×ÒÔÌ«Íø¶Ë¿Ú  £¬Ö§³ÖÍøÏߺ͹âÏË
  • Ö§³Ö Turbo Ring ºÍ Turbo Chain£¨×ÔÓúʱ¼ä < 20 ms @ 250 ̨½»Á÷»ú£©  £¬ÒÔ¼° RSTP/STP/MSTP ÍøÂçÈßÓà
  • 24/48 VDC »ò 110/220 VDC/VAC ¸ôÀëÈßÓàË«µçÔ´ÊäÈë
  • ½ÓÄÉÄ£¿é»¯Éè¼Æ  £¬¶àÖֶ˿Ú×éºÏ¿ÉÑ¡
  • Ö§³Ö -40 ÖÁ 75¡ãC ÊÂÇéζÈ
  • MXstudio ÇáËÉʵÏÖ¿ÉÊÓ»¯¹¤ÒµÍøÂç
  • V-ON? Ö§³ÖºÁÃ뼶×é²¥Êý¾ÝºÍÊÓƵÍøÂç»Ö¸´
Ëù»ñÖ¤Êé
ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IKS-6726A ϵÁÐרΪ¹¤ÒµºÍÉÌÎñÁìÓòµÄÒªº¦Ê¹ÃüµÄÑÏ¿ÁÐèÇó¶øÉè¼Æ  £¬ÀýÈ磺½»Í¨¿ØÖÆϵͳºÍº£ÊÂÓ¦Óá£IKS-6726A Ö§³ÖǧÕ׺ͰÙÕ×ÒÔÌ«ÍøÖ÷¸ÉÍøÂç¡¢ÈßÓà»·ÍøÊÖÒÕ¡¢24/48 VDC »ò 110/220 VAC ¸ôÀëÈßÓàË«µçÔ´ÊäÈë  £¬½ø¶øÌá¸ßͨѶÎȹÌÐÔ  £¬½ÚÔ¼²¼Ïß±¾Ç®¡£
IKS-6726A ½ÓÄÉÄ£¿é»¯Éè¼Æ  £¬ÍøÂçÍýÏëÉèÖÃÔ½·¢ÇáËɺÍÎÞа  £¬¶à¿ÉÒÔ×°Öà 2 ¸öǧÕ×ÒÔÌ«Íø¶Ë¿ÚºÍ 24 ¸ö°ÙÕ×ÒÔÌ«Íø¶Ë¿Ú¡£

ÆäËûÌصãºÍÓÅÊÆ
? ÏÂÁîÐнçÃæ (CLI)  £¬¿É¿ìËÙÉèÖÃÖ÷ÒªÖÎÀí¹¦Ð§
? DHCP Option 82  £¬ÓÃÓÚ²î±ðÕ½ÂÔ·ÖÅÉ IP µØµã
? Ö§³Ö EtherNet/IP¡¢PROFINET ºÍ Modbus TCP ЭÒéµÄ×°±¸ÖÎÀíºÍ¼à¿Ø
? IGMP snooping ºÍ GMRP  £¬ÓÃÓÚ¹ýÂË×é²¥Á÷Á¿
? »ùÓÚ¶Ë¿ÚµÄ VLAN¡¢IEEE 802.1Q VLAN ºÍ GVRP  £¬¿É¼ò»¯ÍøÂçÍýÏë
? QoS£¨IEEE 802.1p/1Q ºÍ TOS/DiffServ£©Ìá¸ßÁËÍøÂçÎȹÌÐÔ
? IEEE 802.3ad¡¢LACP  £¬¿ÉÓÅ»¯ÍøÂç´ø¿í
? ¿ìËÙ»»Ï߻ָ´
? TACACS+¡¢IEEE 802.1X¡¢SNMPv3¡¢HTTPS ºÍ SSH  £¬ÓÃÓÚÔöÇ¿ÍøÂçsafetyÐÔ
? SNMPv1/v2c/v3 Ö§³Ö²î±ð¼¶±ðµÄÍøÂçÖÎÀí
? RMON  £¬ÓÃÓÚ×Ô¶¯µØ¾ÙÐÐÍøÂç¼à¿Ø
? ´ø¿íÖÎÀíͨ¹ý MAC µØµãµÄ¶Ë¿ÚËø¶¨¹¦Ð§  £¬±ÜÃâδ¾­ÊÚȨµÄ»á¼û  £¬¿ÉÔ¤·À·ºÆð²»Îȹ̵ÄÍøÂç״̬
? Ö§³Ö¶Ë¿Ú¾µÏñ¹¦Ð§  £¬±ãÓÚÔÚÏßµ÷ÊÔ
? ͨ¹ýµç×ÓÓʼþºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯·¢³öÒì³£ÖÒÑÔ
? ×Ô¶¯»Ö¸´ÔÚÏß×°±¸µÄ IP µØµã
? ¿Éͨ¹ý web ä¯ÀÀÆ÷¡¢Telnet/´®¿Ú console¡¢CLI¡¢Windows ÖÎÀí¹¤¾ßºÍ ABC-02-USB ×Ô¶¯±¸·ÝÉèÖÃÆ÷¾ÙÐÐÉèÖÃ

ÊäÈë/Êä³ö½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±¨¾¯¹¦Ð§Í¨µÀ £º´¿µç×èÐÔ¸ºÔØ£º1 A @ 24 VDC

ÒÔÌ«Íø½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
10/100BaseT(X) ¶Ë¿Ú£¨RJ45 ÌÖÂÛ£© £º8
Combo ¶Ë¿Ú£¨10/100/1000BaseT(X) »ò 100/1000BaseSFP£© £º2
Ä£¿é £º
2 ¸öÄ£¿é»¯²å²Û  £¬ÊÊÓÃÓÚÈκδøÓÐ 10/100BaseT(X)¡¢100BaseFX£¨SC/ST ÌÖÂÛ£©»ò 100Base SFP µÄ 8 ¶Ë¿Ú»ò 6 ¶Ë¿Ú½Ó¿ÚÄ£¿é ÓйذÙÕ×ÒÔÌ«ÍøÄ£¿éµÄ²úÆ·ÐÅÏ¢  £¬Çë²ÎÔÄ IM-6700A ²úÆ·×ÊÁϱí¡£
±ê×¼ :
IEEE 802.1D-2004  £¬ÓÃÓÚÌìÉúÊ÷ЭÒé (STP)
IEEE 802.1p  £¬ÓÃÓÚЧÀÍÆ·¼¶
IEEE 802.1Q  £¬ÓÃÓÚ VLAN ±ê¼Ç
IEEE 802.1s  £¬ÓÃÓÚ¶àÌìÉúÊ÷ЭÒé (MSTP)
IEEE 802.1w  £¬ÓÃÓÚ¿ìËÙÌìÉúÊ÷ЭÒé (RSTP)
IEEE 802.1X  £¬ÓÃÓÚÊÚȨÈÏÖ¤
IEEE 802.3  £¬ÓÃÓÚ 10BaseT
IEEE 802.3ab  £¬ÓÃÓÚ 1000BaseT(X)
IEEE 802.3ad  £¬ÓÃÓÚ LACP ¶Ë¿Ú¾ÛºÏ
IEEE 802.3u  £¬ÓÃÓÚ 100BaseT(X) ºÍ 100BaseFX
IEEE 802.3x  £¬ÓÃÓÚÁ÷Á¿¿ØÖÆ
IEEE 802.3z  £¬ÓÃÓÚ 1000BaseSX/LX/LHX/ZX

ÒÔÌ«ÍøÈí¼þÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÖÎÀí :
Back Pressure Flow Control£¨±³Ñ¹Á÷Á¿¿ØÖÆ£©¡¢BOOTP¡¢DDM¡¢DHCP Option 66/67/82¡¢DHCP Server/Client¡¢Flow control£¨Á÷Á¿¿ØÖÆ£©¡¢IPv4/IPv6¡¢LLDP¡¢Port Mirror£¨¶Ë¿Ú¾µÏñ£©¡¢RARP¡¢RMON¡¢SMTP¡¢SNMP Inform¡¢SNMPv1/v2c/v3¡¢Syslog¡¢Telnet¡¢TFTP
¹ýÂË :
802.1Q¡¢GMRP¡¢GVRP¡¢IGMP v1/v2/v3
ÈßÓàЭÒé :
Á´Â·¾ÛºÏ¡¢MSTP¡¢RSTP¡¢STP¡¢Turbo Chain¡¢Turbo Ring v1/v2¡¢V-ON
safety :
»á¼û¿ØÖÆÁÐ±í¡¢¹ã²¥·ç±©±£»¤¡¢HTTPS/SSL¡¢MAB ÊÚȨÈÏÖ¤¡¢NTP ÊÚȨÈÏÖ¤¡¢¶Ë¿ÚËø¶¨¡¢RADIUS¡¢SSH¡¢TACACS+
¶ÔʱЧÀÍ :SNTP
¹¤ÒµÐ­Òé :EtherNet/IP¡¢Modbus TCP¡¢PROFINET
MIB :
Ethernet-like MIB, MIB-II, P-BRIDGE MIB, Q-BRIDGE MIB, RMON MIB Groups 1, 2, 3, 9, RSTP MIB

½»Á÷ÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IGMP ·Ö×é :2048
¾ÞÐÍÖ¡¾Þϸ :9.6 KB
MAC µØµã±í¾Þϸ :16 K
Max VLAN ÊýÄ¿ :64
Êý¾Ý°ü»º³åÇø¾Þϸ :12 Mb
ÓÅÏȼ¶ÐÐÁÐ :4
VLAN ID ¹æÄ£ :VID 1 ÖÁ 4094

USB ½Ó¿Ú

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
´æ´¢¶Ë¿Ú :USB Type A

´®¿Ú½çÃæ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
Console ¶Ë¿Ú :USB ´®¿Ú console£¨Type B ÌÖÂÛ£©

µçÔ´²ÎÊý

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊäÈëµçѹ :
IKS-6726A-2GTXSFP-24-T£º24 VDC
IKS-6726A-2GTXSFP-24-24-T£º24 VDC£¨ÈßÓàË«µçÔ´ÊäÈ룩
IKS-6726A-2GTXSFP-48-T£º48 VDC
IKS-6726A-2GTXSFP-48-48-T£º48 VDC£¨ÈßÓàË«µçÔ´ÊäÈ룩
IKS-6726A-2GTXSFP-HV-T£º110/220 VAC
IKS-6726A-2GTXSFP-HV-HV-T£º110/220 VAC£¨ÈßÓàË«µçÔ´ÊäÈ룩
ÊÂÇéµçѹ :
IKS-6726A-2GTXSFP-HV-T£º85 ÖÁ 264 VAC
IKS-6726A-2GTXSFP-HV-HV-T£º85 ÖÁ 264 VAC
IKS-6726A-2GTXSFP-24-T£º18 ÖÁ 36 VDC
IKS-6726A-2GTXSFP-24-24-T£º18 ÖÁ 36 VDC
IKS-6726A-2GTXSFP-48-T£º36 ÖÁ 72 VDC
IKS-6726A-2GTXSFP-48-48-T£º36 ÖÁ 72 VDC
¹ýÔصçÁ÷±£»¤ :Ö§³Ö
·´½Ó±£»¤ £ºÖ§³Ö
ÊäÈëµçÁ÷ £º
IKS-6726A-2GTXSFP-24-T/2GTXSFP-24-24-T£º0.36 A @ 24 VDC
IKS-6726A-2GTXSFP-48-T/2GTXSFP-48-48-T£º0.19 A @ 48 VDC
IKS-6726A-2GTXSFP-HV-T/2GTXSFP-HV-HV-T£º0.28/0.14 A @ 110/220 VAC

»úеÌØÕ÷

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
IP Æ·¼¶ £ºIP30
³ß´ç £º440 x 44 x 280 mm£¨17.32 x 1.37 x 11.02 Ó¢´ç£©
ÖØÁ¿ :4100 g (9.05 lb)
×°Öà :»ú¼ÜʽװÖÃ

ÊÂÇéÇéÐÎ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ÊÂÇéÎÂ¶È :-40 ÖÁ 75¡ãC£¨-40 ÖÁ 167¡ãF£©
´æ´¢Î¶ȣ¨º¬°ü×°£© :-40 ÖÁ 85¡ãC£¨-40 ÖÁ 185¡ãF£©
Ïà¶Ôʪ¶È :5 ÖÁ 95%£¨·ÇÀäÄý£©

°²¹æÈÏÖ¤

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
safety :EN 60950-1  £¬UL 60950-1
EMC :EN 55032/24
EMI :CISPR 32  £¬FCC Part 15B Class A
EMS :
IEC 61000-4-2 ESD£º½Ó´¥£º6 kV£»¿ÕÆø£º8 kV
IEC 61000-4-3 RS£º80 MHz ÖÁ 1 GHz£º10 V/m
IEC 61000-4-4 EFT£ºµçÔ´£º2 kV£»Ðźţº2 kV
IEC 61000-4-5 Surge£ºµçÔ´£º2 kV£»Ðźţº1 kV
IEC 61000-4-6 CS£º10 V
IEC 61000-4-8 PFMF
¹ìµÀ½»Í¨ :EN 50121-4
º£Ê :ABS¡¢DNV-GL¡¢LR¡¢NK
×ÔÓÉÂäÌå :IEC 60068-2-32
¹¥»÷ :IEC 60068-2-27
Õñ¶¯ :IEC 60068-2-6

MTBF

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
ʱ¼ä :149,151 Сʱ
±ê×¼ :Telcordia (Bellcore)  £¬GB

±£ÐÞ

ºèÔ˹ú¼Ê¡¤(Öйú)ÊÖ»ú°æµÇ¼Èë¿Ú
±£ÐÞÏÞÆÚ£º5Äê
OFFICE ADDRESS °ì¹«µØµã
ÁªÏµµØµã£º½­ËÕÊ¡ÄϾ©ÊÐ̫ƽÄÏ·450ºÅ˹ÑDzƲúÖÐÐÄ8Â¥
ÁªÏµµç»°£º025-83682516/7/8/9
ÏúÊÛÈÈÏߣº025-86884206 83376787
ÊÖÒÕÈÈÏߣº025-86884202
άÐÞÈÈÏߣº025-83682516 ת8891
ÁªÏµµØµã£º½­ËÕÊ¡ËÕÖÝÊÐÈËÃñ·3188ºÅÍò´ï¹ã³¡Ð´×ÖÂ¥A×ù1604ÊÒ
ÁªÏµµç»°£º13851489296
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£º°²»ÕÊ¡ºÏ·ÊÊнðկ·162ºÅ¹ú¼ÊÉÌÎñÖÐÐÄA×ù804
ÁªÏµµç»°£º0551-63632876 18761854404
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºËÄ´¨Ê¡³É¶¼»áÇàÑòÇøÌ«ÉýÄÏ·288ºÅ½õÌìÌüÊC×ù
ÁªÏµµç»°£º028-86629990 15895882659
E-mail£ºsupport@mingit.com 
ÁªÏµµØµã£ºÖØÇìÊоÅÁúÆÂÇøл¼ÒÍ廪Èó¹ã³¡
ÁªÏµµç»°£º023-68088529 15895882659
E-mail£ºsupport@mingit.com 
CONTACT US ÁªÏµºèÔ˹ú¼Ê
ЧÀÍÈÈÏߣº025-83682516
Òâ¼û·´ÏìÈÈÏߣº13645192640
¡¾ÍøÕ¾µØͼ¡¿¡¾sitemap¡¿